A 55 × 12 × 2.5 mm UHF RFID laundry tag with a flexible circuit inlay sealed in silicone, rated for up to 200 industrial wash cycles, 60-bar tunnel washers and autoclave sterilisation. Built for hospital, hotel and uniform laundries.

Model:
ID-SLT-5512
Brand:
Identium
Chip:
UCODE 8 or UCODE 9 (other ICs on request)
Frequency:
860–960 MHz (covers India's 865–868 MHz band)
Protocol:
EPC Class 1 Gen2 / ISO 18000-6C
Read range:
Up to 6 m on textiles (rated at 4 W EIRP, 902–928 MHz)
Datasheet:
PDF · 70 KB
Listing updated:

₹45

per piece + 18% GST

Min. order 500 piecesThe final price for your quantity is confirmed in the quote

  • 7-day replacement · 1-year warranty against manufacturing defects
  • Blue Dart next-day delivery
  • Samples ₹250 (1–2 pcs, incl. shipping) · request a sample of this tag

Sold by India RFID Store, the online catalogue of Identium Tech Solutions Pvt Ltd, an RFID manufacturer in New Delhi, India, in business since 2010.

Key features

  • Rated for up to 200 industrial wash cycles in 60-bar tunnel washers
  • Withstands high-temperature drying and autoclave sterilisation
  • Non-magnetic and MRI safe at 1.5 T and 3.0 T
  • Small 55 × 12 × 2.5 mm, 2.1 g silicone body, gentle on fabric
  • UCODE 8 / UCODE 9 chip, 96–128-bit EPC, 20-year data retention
  • Sew, heat-press, paste or pocket it

Overview

ID-SLT-5512 silicone UHF RFID laundry tag for harsh wash cycles

The ID-SLT-5512 seals a flexible printed circuit (FPC) inlay inside silicone. That construction is what lets it handle a commercial laundry: it is rated for up to 200 industrial wash cycles, high-pressure (60 bar) tunnel washers, high-temperature drying and autoclave sterilisation. At 55 × 12 × 2.5 mm and 2.1 g, it is small and soft enough not to damage delicate fabric.

Built for healthcare textiles

Hospitals add two items to the usual laundry checklist. This tag is non-magnetic and rated MRI safe for 1.5 T and 3.0 T scanners, so tagged scrubs and patient gowns can be used in imaging areas, and it tolerates the autoclave cycles used for sterile textiles. See how RFID fits ward and theatre workflows on our RFID for healthcare and hospitals page.

Silicone or woven tag?

Silicone (this tag)

Sealed body with a stated 200-cycle rating. Best where linen sees high-pressure tunnel washing, hot drying or sterilisation.

Woven fabric tag

Softer and label-like, such as the ID-FLT-UFLT. Suits garments where comfort against the skin matters most.

The 6 m read range was rated on textiles at 4 W EIRP in the 902–928 MHz band. On India's 865–868 MHz band, actual range depends on reader power, antenna and how densely linen is stacked. Bulk orders can be pre-encoded, with UCODE 8, UCODE 9 or other ICs on request.

Where the ID-SLT-5512 is used

  • Hospital linen
  • Hotel towels
  • Industrial uniforms
  • Commercial laundries
  • Uniformed services clothing
  • Garment rental
  • Dry-cleaning chains
  • Firefighting gear

Specifications

Datasheet (PDF)
ModelID-SLT-5512
Dimensions55 × 12 × 2.5 mmSee this size at actual size →
Weight2.1 g
ChipUCODE 8 or UCODE 9 (other ICs on request)
Memory96–128-bit EPC
Data retention20 years
Frequency860–960 MHz (covers India's 865–868 MHz band)
ProtocolEPC Class 1 Gen2 / ISO 18000-6C
Read rangeUp to 6 m on textiles (rated at 4 W EIRP, 902–928 MHz)
MaterialFPC (flexible printed circuit) inlay encased in silicone
Wash durabilityUp to 200 industrial wash cycles; rated for high-pressure (60 bar) tunnel washers
SterilisationAutoclave compatible
MRINon-magnetic; compatible with 1.5 T and 3.0 T scanners
MountingSewn, heat-pressed, pasted or placed in a fabric pocket
Material complianceRoHS-compliant materials (maker's declaration)

Frequently asked questions

How many wash cycles can this tag withstand?
It is rated for up to 200 industrial wash cycles, including high-pressure tunnel washers at 60 bar, high-temperature drying and autoclave sterilisation.
What read range will I get in India?
The tag is rated up to 6 m on textiles at 4 W EIRP in the 902–928 MHz band. It covers 860–960 MHz, so it works on India's 865–868 MHz band, where real range depends on reader power, antenna and how densely linen is stacked.
How is the tag attached to garments and linen?
It can be sewn into a seam, heat-pressed, pasted or placed in a small fabric pocket, depending on the garment and wash process. Pick one method per item type so tags sit in a predictable place.
Is it safe for hospital linen and MRI rooms?
Yes. It is non-magnetic and MRI safe, compatible with 1.5 T and 3.0 T scanners, and it survives autoclave sterilisation, which suits hospital linen and scrubs.
Which chip and memory does it use?
A UCODE 8 or UCODE 9 chip on EPC Class 1 Gen2, with 96–128-bit EPC memory and 20-year data retention. Other ICs are available on request, and bulk orders can be supplied pre-encoded.